R&S®EFA50/53 Test Receiver (ATSC)

All measurement functions for ATSC digital TV standard

Features

Overview

The new test receiver, even the basic version, features a wide range of innovative measurement functions, allowing comprehensive, in-depth signal analysis. In addition to measuring general parameters (Fig. 1) such as bit error ratio (BER), more thorough analysis includes:

  • I/Q constellation diagrams (Fig. 2) with user-selectable number of symbols to be displayed, range: 1 to 999 999 999 symbols
  • Frequency spectrum, including automatic shoulder attenuation measurement to FCC recommendation (Fig. 3)
  • Complex channel transmission function (Fig. 4)
  • Received echo signals (ghost pattern, Fig. 5)
  • Histogram I (Fig. 6) with user-selectable number of symbols to be dis-played, range: 1 to 999 999 999 symbols
  • Modulation error ratio (MER), error vector magnitude (EVM), phase jitter and signal-to-noise ratio (Fig. 7)
  • Linearity analysis from amplitude distribution histogram and CCDF referred to the RF signal (Fig. 8 and Fig. 9)
  • History function: long-term monitoring of transmission parameters (Fig. 10)
  • Alarm monitoring window (Fig. 11)
  • and alarm statistics (Fig. 12)
  • Permanent MPEG2 transport stream demodulation (independent from the selected measurement task)
  • Integrated noise generator